Meta Diag

TWINPROBE

TWINPROBE :

TwinProbe is the TEXA tool for acquiring the analogue and digital measurements needed for all conventional diagnostic testing. It comes at a lower price than UNIProbe, its “big brother”, however both share in common outstanding practicality and precision for all automotive service operations. TwinProbe communicates with all TEXA viewing units or with a Windows PC with USB connection or through Bluetooth Technology, allowing the mechanic absolute freedom of movement around the vehicle and in the workshop. The tool can be managed by the IDC5 operating software, or MSS (Measurement System Software) when used on a PC

OSCILLOSCOPE :

TwinProbe is an oscilloscope with two independent analogue channels for inputs up to ± 200V, complete with SIV (Signal information Viewing ) function for interpreting the measured signal. The SIV function guides you through the entire test procedure. TwinProbe not only displays the signal but, while taking measurements and acquiring data, simultaneously processes and analyses information in order to provide real time evaluations. TwinProbe can process signals from various sensors and actuators and compare the data acquired against values stored in the internal database, immediately highlighting any signal anomalies.

SIGNAL GENERATOR :

The practical TwinProbe signal generator is ideal for simulating input signals from sensors and the signals transmitted by ECUs to control actuators like solenoid valves, in order to detect and analyse faults in the system.

AMMETER :

TwinProbe can also be used to measure current intensity. An optional BICOR clamp-on ammeter is needed to allow TwinProbe to run these tests.

MEASUREMENT SYSTEM SOFTWARE :

Easy access to the amazing functions of TwinProbe is ensured by MSS (Measurement System Software), developed by TEXA especially for this device, and by the complete IDC5 software Platform. The SIV (Signal Information Viewing) function deserves a special mention. This uses a software algorithm developed by TEXA specifically to compare acquired data with values recorded in an internal database. Unusual signals can therefore be identified instantly, making your work faster and easier than ever.

TEXA customer services :

TEXA has always supported its tools with a wide range of services. These services keep TEXA tools up to date with the latest innovations in automotive technology, provide practical troubleshooting assistance and guarantee mechanics all-round competence in their field. The TEXPACK annual contract provides updates for all environments, while TEX@info provides access to the latest technical bulletins, the “SOLVED PROBLEMS” database powered by Google, the Call Centre and iSupport. TEXA also runs a virtual store that can be accessed directly from TEXA software, in which users can request the activation of a large number of apps for the world of vehicle diagnostics and repair. Click the link below to find out more about TEXA’s services.  

TECHNICAL SPECIFICATIONS

POWER SUPPLY 8 V – 35 V DC max STAND-BY CONSUMPTION 150 mA at 12 V CONSUMPTION DURING BATTERY CHARGE IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS 480 mA at 12 V INTERNAL BATTERY DURATION IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS 1h and 45 mins approximately ENVIRONMENTAL  Operational temperature: 0 ÷ +45°C Storage temperature: – 20 °C ÷ 60 °C Operating relative humidity: 10% – 80% DIMENSIONS WITHOUT CABLES (WITH CABLES)  125 x 130 x 27 mm (135 x 130 x 27 mm) WEIGHT 460 g. OSCILLOSCOPE CHANNEL NUMBERS 2 analogue (CH01, CH02) HOST CONNECTION Via USB2, USB1 or Wireless Bluetooth. TRIGGER CH01 o CH02 A/D CONVERSION 2 10-bit converters. 40 MS/s with one active channel. 20 MS/s for channel with 2 active channels. VIEWING MODE Normal, Auto, Single shot. COMMON MODE AC, DC MAX INPUT VOLTAGE ± 200 V ADDITIONAL FUNCTIONS Trigger delay, frequency calculation, Vmedia, Vmax, Vmin, Period, Setting scale for amperometric clamps.. SIGNAL GENERATOR PWM CURRENT DRIVE Maximum continuous current: 5 A @ 12 V Maximum PWM frequency: 50 kHz Operating voltage: 5÷30 V Duty Cycle Resolution: 1% Frequency resolution: 0,1 Hz PWM 5 V: Maximum continuous OUTPUT current: 20 mA Maximum PWM frequency: 50 kHz OUTPUT voltage: 0-5 V ± 5% Duty Cycle Resolution: 1% Frequency resolution: 0,1 Hz